Showing posts with label Application Designer. Show all posts
Showing posts with label Application Designer. Show all posts

Tuesday, February 10, 2015

Application Designer Compare Report Slow

Recently After upgrade to People Tools 8.53 from PT 8.50, We have noticed that for a large project (611 items) compare report is running really slow taking more than 1 hour. This was even more slow (3 hours) if the database is located in remote data center.

Since People Tools 8.51 , PeopleSoft added the ability to write compare reports to database tables which was really causing this slowness.

If you are not planning to use the database tables to review compare reports, please do the following to speed the compare report process.

Go to Compare and Report –> Options

Select Report Option Tab and Uncheck Generate Output to tables.

image

This fixed the issue. you can also truncate the below tables if you do not need to store the previous version of compare reports.

truncate table PSCOMPDEFN;
truncate table PSCOMPITEM;
truncate table PSCOMPITEMDATA;
truncate table PSCOMPSESSION;
truncate table PSCOMPOBJDIFF;
truncate table PSCOMPOBJLONG;

The first 3 tables are no longer used in PT 8.54

MOS (My Oracle Support Articles)

E-UPG PT8.51+: Are Tables Updated with Compare Report Data? (Doc ID 1290456.1)

E-COMP: Generate Output To Tables Option Not Writing Results To The Tables In 8.54 (Doc ID 1958074.1)

E-PUM: How to Improve Performance on Step "Comparing ADS MO Project From File" (Doc ID 1965298.1)

Also you can export the configuration manger config file and add the following under PSIDE section below after line : UpgXmlOutput=REG_DWORD=0

UpgTblOutput=REG_DWORD=0

You can then use this config file to install other workstations with same configuration.

Alternatively, you can add the below to a notepad and save as psidecompare.reg and ask user to run it manually to change the setting.

Windows Registry Editor Version 5.00

[HKEY_CURRENT_USER\Software\PeopleSoft\PeopleTools\Release8.40\PSIDE]
"UpgTblOutput"=dword:00000000

Tuesday, October 14, 2014

Unable to Select or Edit a Field on a Page in Application Designer

On a very long page, we were not able to select the fields towards the bottom of this page. We found the following in PeopleBooks

Home -> PeopleSoft PeopleTools 8.53 -> PeopleSoft Application Designer Developer’s Guide -> Understanding Page Controls -> Data Entry Controls

Note: PeopleSoft Application Designer allows you add up to 405 fields on a page. When you reach this limit, typical system behavior includes being unable to select, move, or edit the page fields with an order number exceeding the 405-field limit. While this limit has no effect on the page at runtime, it has the potential to disrupt productivity during design time. If you find a page nearing the 405-field limit, you should use subpages to decrease the number of fields on a single page.

Below PeopleSoft resolution describes the same issue which is there since Version 8.2

E-AD Is there any limit on the number of fields on a Page Definition ( Doc ID 648823.1 )

Using Sub pages is the easiest way to resolve this issue. However this require changing the code.

The below query can be used to identify any such pages

select pnlname,count(*) from pspnlfield group by pnlname order by count(*) desc